Specification Sheet Up to 12 Keypads - up to 8 hardwired keypads and 4 wireless keypads
- 4 hardwired keypads available with zone input…
| - | PC5508Z eight zone LED keypad | | - | PC5516Z sixteen zone LED keypad | | - | PC5532Z thirty two zone LED keypad | | - | LCD5500Z alphanumeric keypad |
- WLS910… wireless handheld keypad
- added wireless control is provided by …
| - | WLS908… wireless panic pendant | | - | WLS909… wireless key |
32 Zones Hardwired or Wireless … 2 Partitions Hardwired - 8 zones on main panel
- PC5108 - 8 zone expansion module
- PC5108L - 8 zone expansion module plus Downlook video on Power832 PC5015 panel
- PC5700 …Canada only - 4 general purpose zones, 2 waterflow zones, 1 ground fault zone, plus dual supervised telephone lines
- PC5720 …Canada only - 5 general purpose zones, 2 waterflow zone, 1 ground fault zone, plus printer or DVACS communications
Wireless - PC5132 - 32 zone wireless zone expansion module
14 PGM Outputs - up to 5 high current outputs… 1 on main panel plus :
| PC5204 | - | 4 output high current power supply module | | - | 1 output fully supervised for siren output |
- up to 9 low current outputs… 1 on main panel plus :
| PC5208 | - | 8 low current output module |
|
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
| Advanced Communications
- supports all major formats including SIA and Contact ID
- LINKS1000™ cellular communication
- LINKS2150™ and LINKS2450™ long range radio communication
- DVACS communication using PC5400 or PC5720 modules
- Downlook video transmission using PC5108L module on Power832 PC5015 main control panel
- event initiated personal paging
- 3 phone numbers (3rd backs up primary number)
- 2 account numbers
Integrated Intercom Audio
- supports Central Station Two Way Voice and Home Intercom features using PC5928 audio interface module, PC5921 intercom stations, and PC5904 two way listen-in stations
Integrated CCTV
- supports Downlook still frame video transmission using PC5108L module on Power832 PC5015 main control panel
- provides local VCR/monitor video switching for 8 cameras
Integrated Voice Assisted Security & Home Automation
- Escort5580 & 5580TC provide voice assisted security and automation control for up to 32 X-10 devices plus thermostat control on 5580TC
Efficient Installation
- 4 wire communications bus (KEYBUS)
| | - | connect modules up to 1000' (305m) from control panel | | | - | PC5204 - 4 output high current power supply module provides up to 1A auxiliary power | | | - | main panel provides up to 550mA auxiliary power |
|
|
Top of Page
| · P o w e r 8 3 2 S e c u r i t y S y s t e m · |
|  PC5010/5015 Main Control Panels
|
| - PC5010 main control panel - alarm only
- PC5015 main control panel - alarm plus Downlook video capability
- support up to 32 zones using any combination of up to :
| - | 8 hardwire zones on main panel | | - | 8 hardwire zones using PC5108L video matrix module (on PC5015 only) | | - | 4 general purpose hardwire zones and 2 waterflow hardwire zones using PC5700 fire module (in Canada only) | | - | 24 hardwire zones using PC5108 eight zone expander modules | | - | 8 keypad zones | | - | 32 wireless zones using PC5132 wireless receiver module |
- zone programming
| - | all zones programmable as burglary or fire | | - | zone options include : Normally Closed loop, Single End of Line (EOL) resistor, and Double EOL resistor * * keypad zones cannot be programmed as fire zones and cannot support Double EOL resistor supervision | | - | 27 programmable zone types, 8 programmable zone options |
Top of Page - audible alarm output
| - | supervised bell output - 700 mA @ 12VDC, PTC protected, current limited at 3 A | | - | steady, pulsed, temporal pattern, or strobe fire output | | - | additional supervised siren output is available using PC5204 power supply module |
- programmable voltage outputs
| - | 1 high current 300mA PGM… can also be used for 2 wire smoke with a maximum of 20 detectors at 15mA per detector | | - | 1 low current 50mA PGM | | - | 8 additional low current PGM outputs using PC5208 module | | - | 4 additional high current PGM outputs using PC5204 module | | - | 24 programmable options |
- local PCLINK™ and remote upload/download capability
| - | program system using DLS software and direct PC connection to control panel or via remote PC over telephone line | | - | view status and trouble conditions, and system 128 event buffer | | - | remote access can be controlled by owner to prevent unauthorized access to system |
Top of Page - power supply
| - | 550mA @ 12.5VDC auxiliary power (400mA for UL applications) | | - | positive temperature coefficient (PTC) protected battery, AUX, and Bell output | | - | electronic protection of KEYBUS | | - | supervision of AC power loss, low battery, auxiliary power failure | | - | internal clock locked to AC power frequency |
- EEPROM memory
| - | will not lose programming or system status on complete AC and battery failure |
Top of Page - digital communicator
| - | supports all major formats including SIA & Contact ID | | - | supports LINKS1000™ cellular communications | | - | supports LINKS2150™ and LINKS2450™ long range radio communications | | - | 3 phone numbers (3rd backs up primary) | | - | 2 account numbers | | - | DTMF or pulse dialing | | - | DPDT line seizure | | - | anti-jam feature | | - | split reporting of selected events to each telephone number | | - | event initiated personal paging |
- battery required : 12V, 4 Ah, rechargeable sealed lead acid
- transformer required : 16.5VAC, 40VA
|
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
| |  System Operation 2 system partitions… 2 account numbers | - | each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features |
- 38 - 4 or 6 digit access codes
| - | 32 user codes, 1 system master code, 2 partition master codes, 2 duress codes, and 1 maintenance code |
- automatic arming by partition
| - | each partition may be programmed to auto-arm at its own time each day |
- keypad lockout
| - | panel can be programmed to lockout keypad if a series of incorrect access code entries are made |
- 'quick arm' and 'quick exit'
| - | allows users to arm and exit easily |
- 'stay/away' zones and 'stay' arming
| - | security of perimeter arming while premise is occupied |
- door chime
| - | programmable by zone | | - | monitor a door by having keypad beep when the door is opened and again when door is closed |
128 event buffer | - | all events automatically stored with time and date stamp to buffer | | - | events can be printed on-site using the PC5400 serial printer interface module, viewed through an LCD Keypad, or viewed and printed via PC using DLS software |
 Full Supervision The system continuously monitors the following trouble conditions : - AC power failure
- trouble by zone
- fire trouble
- telephone line trouble
- low battery
- bell output trouble
- loss of internal clock
- tamper by zone
- fail to communicate
- aux power supply fault
- module fault (supervisory or tamper)
- camera troubles (on PC5015 with Downlook)
 False Alarm Prevention Features
- audible exit delay
- audible exit fault
- quick exit
- urgency on entry delay
- swinger shutdown
- cross zone alarm
- recent closing transmission
- burglary verified timer *
- double hit timer *
- communication delay
- rotating keypress buffer
- arm/disarm bell squawk
* on PC5015 v2.2x and higher
|
|
Top of Page
| · E x p a n d a b l e H y b r i d S e c u r i t y S y s t e m · |
|  Interfaces & Expansion Modules
|
|  LCD5500Z Plain Language Keypad
The Power832 security system is fully programmable from the attractive, easy to use dual-language LCD5500Z keypad :
- connect up to 8 keypads, combination LED and/or LCD
- zone input
| - | connect detector to keypad to avoid separate wiring back to panel |
Top of Page - multi-language (languages vary according to country)
| - | simple key entry to toggle between languages while viewing keypad |
- rotating keypress buffer reduces access code entry false alarms
- large 32 character display
| - | zone identification | | - | system instructions | | - | system status | | - | 128 event buffer | | - | trouble conditions |
- plain language operating instructions
| - | menu for user functions | | - | what key to press for specific functions | | - | steps for programming functions |
Top of Page - automatic scrolling of alarms in memory
| - | scrolls through alarms in memory while keypad is idle |
- 12 hour or 24 hour clock display
- 5 programmable function keys with 25 options such as Home Arm, Away Arm, Quick Exit etc.
- 4 keypad-activated alarms : Fire, Auxiliary, Panic, and Duress
- 3 LED indicators : Ready, Armed and Trouble
| - | allow system status to be viewed at a glance |
Top of Page - backlit display
| - | display and keys backlit for easy viewing in low light conditions | | - | adjustable brightness and contrast | | - | Backlighting Boostprovides extra high key lighting when any key is pressed |
- piezo buzzer
| - | provides audible feedback for correct key entries, pre-alert, and system trouble status | | - | adjustable buzzer tone |
- connect to 4 wire KEYBUS up to 1000' (305m) from control panel
- specifications
| - | current draw : 85mA with backlighting boost | | - | dimensions : 5.75" W x 4.5"H x 1" D (144 x 114 x 25mm) |
|
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
| |  LED Keypads
The Power832 system is fully programmable from any of the attractive, easy to use, LED keypads : - 3 keypads available :
PC5508Z ........ 8 zone LED keypad PC5516Z ........ 16 zone LED keypad PC5532Z ........ 32 zone LED keypad - zone input
| - | connect detector to keypad to avoid separate wiring back to panel |
- rotating keypress buffer reduces access code entry false alarms
- 5 programmable function keys with 25 options such as Home Arm, Away Arm, Quick Exit etc.
- LED indicators : Ready, Armed, Trouble, Memory, Bypass, Fire, Program
- 4 keypad-activated alarms…Panic, Auxiliary, Fire, and Duress
- backlit display…with Backlighting Boost to provide extra high key lighting when any key is pressed
- piezo buzzer…provides audible feedback for correct key entries, pre-alert, and system trouble status… with adjustable buzzer tone
- connect to 4 wire KEYBUS up to 1000' (305m) from control panel
- specifications
| - | current draw : 85mA with backlighting boost | | - | dimensions : 5.75" W x 4.5"H x 1" D (144 x 114 x 25mm) |
 PC5400 - Printer Interface Module
- both PC5400 and PC5400DV may be used at the same time on a system
- provides RS232 serial printer connection for report of events logged to the system event buffer… prints event, partition, time, and date that event occurred
- supports any 300, 1200, 2400 or 4800 BPS serial printer
- connect printer up to 200' (61m) from PC5400
- connect PC5400 up to 1000' (305m) from control panel via KEYBUS
- current draw : 65mA @ 12VDC
- maximum one module per system
|
|
Top of Page
| · P o w e r 8 3 2 S e c u r i t y S y s t e m · |
|
|  PC5400DV - DVACS Interface Module |
- both PC5400 and PC5400DV may be used at the same time on a system
- provides ULC Level 3 Line Security.
- provides full DVACS reporting of all system events.
- module is pre-programmed to SIA zone definitions
- events simultaneously communicated via DVACS and other installed communications mode such as digital or cellular
- full cross supervision between the system control panel and the DVACS module e.g… problems with one will be communicated to the central station by the other.
- central station requires Sur-Gard receiver with DVL2A version 2 or higher software.
- complete with 8 pin jack, and communications and power cables for connection to F1/F2 subset.
- connect up to 1000' (305m) from control panel via KEYBUS
- module current draw : 65mA @ 12VDC
Top of Page  Hardwired Expansion |
 PC5108- 8 Zone Expansion Module
- adds 8 hardwired general purpose burglary or fire zones
- provides 100mA @ 12VDC auxiliary current, PTC protected
- connect up to 1000' (305m) from control panel via KEYBUS
- module current draw : 35mA @ 12VDC
...Canada only PC5700 Fire Zone Expansion Module
- a zone expansion module which provides:
| - | dual supervised telephone lines | | - | 2 Class A supervisory waterflow zones | | - | ground fault detection zone | | - | 4 general purpose fire or burglary zones |
- tamper and trouble reporting codes
- connect up to 1000' (305m) from control panel via KEYBUS
- module current draw: 150mA @ 12VDC
...Canada only PC5720 Fire/ Printer / DVACS Module
- a zone expansion module which can also be used to provide either a serial printer or DVACS communications interface
- 8 zone inputs include :
| - | 2 Class A supervisory waterflow zones | | - | ground fault detection zone | | - | 5 general purpose fire or burglary zones |
- as RS232 printer interface :
| - | baud rates… 300, 1200, 2400, 4800 | | - | connect printer up to 200' (61m) from the PC5720 module |
- as DVACS interface :
| - | provides ULC Level 3 Line Security. | | - | provides full DVACS reporting of all system events. | | - | module is pre-programmed to SIA zone definitions |
|
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
| | | - | events simultaneously communicated via DVACS and other installed communications mode such as digital or cellular | | - | full cross supervision between the system control panel and the DVACS module i.e… problems with one will be communicated to the central station by the other. | | - | central station requires Sur-Gard receiver with DVL2A version 2 or higher software. | | - | complete with 8 pin jack, and communications and power cables for connection to F1/F2 subset. |
- connect up to 1000' (305m) from control panel via KEYBUS
- module current draw @ 12VDC : 80mA standby, 100mA with printer, 120mA with DVACS
Top of Page
 Wireless Expansion |
|  PC5132 Wireless Receiver |
|  |  |
|
- add up to 32 DSC wireless detectors * including :
| - | WLS904 ........ passive infrared detector | | - | WLS906 ........ photoelectric smoke detector | | - | WLS907 ........ slim-line transmitter | | * devices use standard Eveready | | Energizer® alkaline batteries |
- 900 MHz true 'Spread Spectrum' technology, fully supervised for communication integrity
- easy sensor enroll process
- supervisory transmissions every 12 minutes
- programmable 1-24hr supervisory window
- connect up to 1000' (305m) from control panel via KEYBUS
- module current draw : 130mA @ 12VDC
 Wireless Control Devices
WLS908 Wireless Panic Pendant | - | communicates a non-medical alarm to central station | | - | 32 pendants maximum…each occupying 1 alarm zone | | - | sealed non-replaceable battery |
WLS909 Wireless Key | - | remote arm/disarm control | | - | up to 16 keys per system | | - | 3 photo/electronic 1.5 V batteries included |
WLS910 Wireless Hand-Held Keypad | - | personal remote keypad | | - | up to 4 wireless keypads per system (in addition to hardwired keypads) | | - | 3 'AAA' batteries included |
|
Top of Page
| · E x p a n d a b l e H y b r i d S e c u r i t y S y s t e m · |
|
|  Integrated Voice Assisted Security & Home Automation |
 ESCORT 5580 Voice Assisted Security & Automation Control Module
- turns any touch-tone phone into a fully functional keypad with Global and Partition control
- built-in power line interface for control of 32 X-10 automation control devices
| - | 16 schedules with On Time, Off Time, and Day of Week | | - | 8 user controlled automation modes | | - | full range of dimming levels for lighting control | | - | event activated control for any PGM output supported by the main panel |
- an extensive library of voice prompts for security and automation operation, programming, and system status feedback
| - | 250 system words for pre-programmed system functions | | - | 240 word library for user programmable voice prompts for Automation Item Labels, Automation Mode Labels, Partition Labels, and Zone Labels |
Top of Page - program up to 6 words per voice label
- powerful 'say number' command can announce numbers from 0-999 in three different ways
- connect up to 1000' (305m) from control panel via KEYBUS
- module current draw: 150mA @ 12VDC
Top of Page
 ESCORT 5580TC
- all the features of the Escort 5580 plus thermostat control
- supports up to four EMS-100 thermostats
- EMS-100 has 4 temperature control modes:
| - | day occupancy mode | | - | night occupancy mode | | - | auxiliary occupancy mode | | - | away occupancy mode |
- each thermostat optionally supports :
| - | up to six EMS-IDS remote indoor temperature sensors for interior temperature averaging | | - | one EMS-ODS outdoor temperature sensor for display of outdoor temperature |
|
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
| |  Integrated Intercom Audio Interface |
 PC5928 Audio Interface Module with PC5921 Series Intercom Stations & PC5904 Two Way Listen-In Stations
 | PC5921 Internal Intercom Station also available : PC5921EXT…external intercom station PC5921EXT/R…external intercom station with relay for operation of existing door bell |
- PC5928 Audio Interface Module
| - | provides 7 output ports for connection of PC5921 Series Intercom Stations | | - | connect up to 1000' (305m) from control panel via KEYBUS |
- local intercom functions :
| - | page/answer | | - | do not disturb | | - | doorbell function | | - | door strike release |
- listen-in broadcast …allows any station to be programmed as a 'broadcast station' to which all other internal stations in the system may listen in
- programmable as sounder for fire/burglar alarms
- answer telephone calls received on regular voice line
| - | ringing programmable by station | | - | supports call waiting | | - | allows call transfer to in-house phones |
- audio user help
| - | provides plain language prompts for system programming, operation, and system status reports when installed with Escort 5580 Voice Prompt Module and keypads mounted with PC5921 Intercom Stations |
- PC5904 central station 2-way listen-in station
| - | programmable control tones (from central station) | | - | select zone, listen/talk, extend on-line time, hang up |
|
|
Top of Page
| · P o w e r 8 3 2 S e c u r i t y S y s t e m · |
|
|  Integrated CCTV |
 PC5108L Downlook Interface Module ***for PC5015 only ***
- provides an interface between the PC5015 alarm control panel and the Downlook DLM-4 still frame video transmission module
- communicates alarm followed by video over a single telephone line in one transmission to a Sur-Gard MLR2 digital receiver
- 8 inputs for video cameras, VCRs, or video switchers
Top of Page - 8 general purpose burglary or fire alarm zone inputs
- any alarm zone (up to 32) or group of zones can be programmed to initiate video capture of 4 frames from any 4 sources - in any sequence
- programmable on-site sequential video switcher mode
| - | view and capture images on a monitor / VCR setup | | - | select cameras for viewing manually using an LED keypad or program system to switch automatically between selected cameras at programmed dwell times |
- supervised by main panel
- programmable via downloading using modem or direct PC-Link
Top of Page - connect up to 1000' (305m) from control panel via KEYBUS
- module current draw : 60mA @ 12VDC

|
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
| |  PGM Output Expansion |
 PC5204 Power Supply/ High Current Output Module - provides 1A @ 12.5VDC auxiliary power for additional modules and devices
- includes 4 fully programmable high current outputs
| - | rated at 1 A @ 12VDC, PTC protected | | - | will provide 3 A short term if battery backup connected | | - | each output can sink up to 3A |
- output #1 may also be used as a supervised bell output
- each output programmable to activate for any of 24 options
- connect up to 1000' (305m) from control panel via KEYBUS
- fully supervised for : tamper, low battery, AC power loss, and auxiliary power trouble
- maximum 1 module per system
- module current draw : 20mA @ 12VDC
- battery required : 4Ah minimum
- transformer required : 16.5VAC, 40VA
 PC5208 Low Current Output Module - module provides 8 low current transistor switch outputs
| - | each output can sink up to 50mA | | - | up to 250mA max at one time |
- each output programmable to activate for any of 24 options
- connect up to 1000' (305m) from control panel via KEYBUS
- fully supervised for tamper
- maximum 1 module per system
- module current draw : 20mA @ 12VDC
|