Broshure | | | Top of Page | Communications...an extensive range of options! - Digital
- Cellular
- Long Range Radio
- Event Initiated Paging
|
| | | | PC4010 / PC4020... Expandability that's built-in for installation flexibility and economy! Start with 8 or 16 zones and expand to 64 or 128 by choosing the best combination of technologies to suit the job at hand: COMBUS expansion… add zone input modules right up to 64 or 128 zones, as well as a host of other output modules, relay modules, etc… all on a 4-conductor non-shielded station wire bus. ADDRESSABLE LOOP expansion… built right onto the main panel, addressable loops make zone expansion simple using DSC addressable devices. Add 56 or 112 addressable devices for panel expansion to full capacity of 64 or 128 zones. WIRELESS expansion… makes filling the gap where hardwiring is difficult, disruptive, or cost prohibitive as easy as connecting a MAXSYS 64 zone wireless receiver to the COMBUS and choosing from an array of DSC wireless components including PIRs, door contact modules, smoke detectors, emergency pendants, and for flexibility of control – 4 button key fobs and handheld keypads. |
|
| | Top of Page | | LOADED WITH FEATURES "RIGHT OUT OF THE BOX" | | · | 4 or 8 system partitions | | · | 1,000 user codes | | · | 3,000 event buffer | | · | 30 programmable zone types | | · | 59 programmable output options | | · | local and remote upload/download | | · | 99 date schedules | | · | 50 arm/ disarm schedules | | · | 99 open/ close suppression schedules | | · | two-year holiday scheduling | | · | automatic daylight savings adjustment | | · | add up to 16 LCD keypads | | · | add up to 64 programmable relays | | · | add up to 144 low power outputs | | · | add point/graphic annunciation | | · | UL & ULC listed for : · residential · commercial applications | | · | And much more… |
|
|
|  |
| |  | | | | | COMBUS... input zone modules, low power outputs, programmable relays, access control modules, remote annunciators all connected to the main panel via a 4-wire, #22 AWG non-shielded cable. With input/output modules located remotely - on up to 4 runs of 1,000 feet (305m) each - home-run wiring is eliminated and the installation is simplified for the installer. | | | |
| |  | | | Plain Language Keypads... What could be more user-friendly! Take the mystery out of security system operation with up to 16 easy to read 32 character LCD keypads, each with five programmable function keys to make regular operations a snap. Connected to the COMBUS, keypads can be assigned for global or partition usage. |
| Top of Page | | | | Adressable Loops... Make expansion easy and economical! Right out of the box – ready to go – no modules to add – expand the system to full zone capacity with 2-wire addressable loops built right onto the main panel. Addressable loops reduce costs through minimum module and wire usage… for maximum installation efficiency and economy!
| | | | Addressable Devices...
| AMA-100 | - | Glassbreak detector | | AMB-300 | - | PIR motion detector | | AMB-500 | - | Ceiling mount PIR motion detector | | AMB-600 | - | Pet-immune PIR motion detector | | AMP-700 | - | Door/ window contact | | AMP-701 | - | Point module – 3 NC inputs | | AMS-220 | - | Photoelectric smoke detector | | AMS-220T | - | Photoelectric smoke detector w/ 135° heat detector | | | | | |
| |
|
|
| |  | | | Remote Zone Expanders... Flexibility at hand! Need to add 8 zones here, 16 zones there? Go right ahead with MAXSYS remote zone expanders. Simply connect them to the COMBUS for flexible, efficient, distributed zone expansion. | |  | | | Wireless Expansion... Convenience and protection! For those hard to wire locations, add up to 64 wireless zones; and for personal protection and operating convenience add up to 64 emergency pendants, 16 key fobs, and 4 handheld keypads using DSC's proven 900MHz true spread spectrum wireless technology. |
| | | | Remote Annunciation... Information in plain sight! DSC's unique point or graphical annunciators can display up to 144 zone, partition, and system events, providing critical information for operating and emergency service personnel. Easy to install, with just 4 wires to the COMBUS the PC4632/PC4664, 32/64 point annunciators provide direct system status and can be flush-mounted for an attractive installation.
| | | |  | | |
|
|
|
| | | PC4701 Fire Module... With the 2 supervised communicator outputs critical to all commercial fire alarm systems, the PC4701 included with the main control panel also provides smoke detector and water flow zones, as well as fire alarm-actuated and fire trouble-actuated output relays. | | PC4204CF Quad Relay & Power Supply Panel... Packaged in an enclosure with transformer and battery charger to meet UL864 requirements, the PC4204CF is the fire version of the PC4204 for security systems. Each PC4204(CF) provides added power for the COMBUS plus 4 high current relays. With up to 16 PC4204(CF) modules, the system can include a total of 64 fully programmable relays. |
| | | Top of Page | |

| Fire Zone Annunciation... Fire specific information at a glance! Especially designed for fire systems, the PC4612 complements the use of standard PC4632/ PC4664 annunciators, which may be used on the same fire system, by adding specific annunciation for fire alarm zones, fire supervisory zones, and fire troubles. | | |
|
|
| | | | PC4010CF / PC4020CF... with UL864 Commercial Fire listings… plus…all the features of MAXSYS security systems! Take a MAXSYS security system with fire savvy software and specially engineered fire application hardware, and not only do you have a great security system, you also have a powerful fire alarm system. | | PC4702BP Dual Bell Output Panel…
Complete with integral transformer and battery charger, the PC4702BP connects to the COMBUS wherever required to provide audible & visual fire alarm notification zones. With up to 4 panels per system, 8 zones total, and each zone providing 1.8 Amps at 24 VDC, MAXSYS solves the power issues for fire alarm strobes and horns. | | Addressable Smoke detectors... Use addressable loops to add up to 56 DSC UL/ ULC listed addressable smoke detectors on PC4010CF systems and 112 on PC4020CF systems to meet the needs of large applications efficiently and economically. | | Universal Remote Zone expansion... Use any mix of listed security and fire alarm detectors on the same zone expanders as the MAXSYS security system. Commercial Fire zones can be standard fire, water flow, auto-verify fire, and fire supervisory. |
|
|  | | | Fire keypads... MAXSYS has a full line of fire keypads with all the features of MAXSYS security keypads plus red bezels and special Fire System defaults for the 5 function keys including : - Silence Trouble
- Silence Bells
- Fire Reset
- Fire Drill
- Lamp Test
| | Top of Page | PS4350R External Battery Charger… Complete with integral transformer, the PS4350R provides the large capacity battery backup power supply required by commercial fire alarm systems. |
| | | | | Special Software Features for Fire… Alarm Auto-Scroll…displays fire alarms and selected fire troubles at two second intervals on all system keypads. Fire Drill…user-initiated for easy evacuation drills. Fire Inspector's Test…simplifies system verification testing. Auto-Verify…programmable by zone for 2-wire, 4-wire and addressable smoke detector zones. Waterflow Delay…programmable timer for waterflow zones. Fire Silence Inhibit…prevent manual signal silence for a programmable time period. Synchronized Temporal Pattern…automatic synchronized audible alarm notification for zones programmed with the temporal pattern. | | |
|
|
| | |
| | | PC4820 Dual Reader Access Control... integrates Access Control with MAXSYS fire and security systems for single system responsibility! | | Supporting a Complete Line of Readers...
| · | Polaris Mag-stripe | | · | ShadowProx proximity | | · | HID proximity | | · | 26 Bit standard Wiegand |
 T.Rex Exit Detectors…
Hands-free, automatic, no buttons to push ! Designed specifically for access control applications, the T.Rex provides fast, accurate detection and door unlocking. | | | Features | | · | up to 16 dual reader panels for 32 readers per system | | · | full standalone operation… complete card database & all programming is maintained in the PC4820's non-volatile memory | | · | arm/ disarm partitions & postpone autoarm by access card or access card and code…from outside the protected space | | · | 64 access levels | | · | 99 seven-day schedules | | · | 4 two year holiday groups - 730 holidays | | · | individual door unlock schedules | | · | automatic switching between daylight savings & standard time | | · | program via keypad, or via computer with DLS-2 upload/download software |
|
|
|
|
| |
Escort4580 Voice Assisted Security and Automation Control Module… The Escort4580 operates in conjunction with any touch-tone telephone to provide an easy to understand plain language interface for MAXSYS Security Systems. Escort allows the telephone to be used as a keypad while providing the user with operational and programming voice prompts as well as plain language system status reports. In addition, Escort acts as an interface for up to thirty two X-10 automation control devices complete with voice assisted operation and programming. | |
PC4400 Printer or DVACS Output module… Use as a true RS-232 serial interface to a serial printer and receive comprehensive management information reports from MAXSYS' 3,000 event buffer or, in Canada, optionally use the PC4400 as a DVACS interface to take advantage of available high security DVACS communications networks. |
| | | PC4010 ................ 8 to 64 zone control panel PC4216 .............. 16 zone low power output module PC4010AR ............ Attack-resistant version PC4204 .............. Quad relay and power supply module PC4020 ................ 16 to 128 zone control panel PC4632 .............. 32 point or graphical display panel PC4020AR ............ Attack-resistant version PC4664 .............. 64 point or graphical display panel PC4108A/T .......... 8 zone expansion module/Tamper PC4400 .............. Printer or DVACS output module PC4116 ................ 16 zone expansion module PS4350 .............. External battery charger | |
| | | LCD4500 .............. LCD keypad LCD4500T ............ LCD keypad with tamper LCD4501 .............. LCD keypad with 5 function keys LCD4501T ............ LCD keypad with 5 function keys & tamper | |
| | | US/INT'L Models ........CDN Models PC4010CF ... PC4010CF ... 8-64 zone Fire/ Security control panel PC4020CF ... PC4020CF ... 16-128 zone Fire/ Security control panel PC4702BP .... n/a ... Dual bell output panel with integral transformer PC4204CF...n/a ... Quad relay and power supply panel with integral transformer PC4612 ... PC4612 ...Fire zone annunciator PS4350R .... PS4350R .... External battery charger | |
| | | PC4820 .............. Dual reader access control panel | |
| | | Escort4580 ......... Voice assisted security and X-10 automation control module | |
| | | PC4164RS*............ 64 zone wireless receiver WLS904* .............. PIR motion detector WLS908 ............ Emergency pendent WLS906* .............. Photoelectric smoke detector WLS909*............ 4 button key fob WLS907* .............. Slim-line transmitter (door/window contact) WLS910 ............ Handheld keypad * 433 MHz versions - available soon | |
| | | AMA-100.............. Glassbreak detector AMS-220............ Photoelectric smoke detector AMB-300.............. PIR motion detector AMS-220T ........ Photoelectric smoke detector w/135° heat det. AMB-500.............. Ceiling-mount PIR motion detector AMP-700............ Door/ window contact - magnet-actuated AMB-600.............. Pet-immune PIR motion detector AMP-701............ Point module - 3 NC inputs | | | | |  | |
|
| | | 